Original Delta PLC controller DVP60EC00R3 EC3 series 100-240VAC 36DI 24DO relay output in box Обустройство дома - купить
Специальная цена от 23 799,75 руб.*
Категория товара: Контроллер двигателя
История изменения цены
*Внимание! Указанная цена 23 799,75 руб. уже могла изменится, перед тем как купить данный товар перейдите на страницу продавца и проверьте актуальную стоимость.
| Месяц | Мин. | Макс. | Цена |
|---|---|---|---|
| 13.05.2026 | 30225.41 | 30830.1 | 30527.5 руб. |
| 13.04.2026 | 24513.57 | 25003.46 | 24758 руб. |
| 13.03.2026 | 29749.31 | 30344.46 | 30046.5 руб. |
| 13.02.2026 | 29511.91 | 30101.95 | 29806 руб. |
| 13.01.2026 | 23561.55 | 24032.66 | 23796.5 руб. |
| 13.12.2025 | 29035.89 | 29616.96 | 29325.5 руб. |
| 13.11.2025 | 28797.51 | 29373.41 | 29085 руб. |
| 13.10.2025 | 28559.33 | 29130.96 | 28844.5 руб. |
Купить Original Delta PLC controller DVP60EC00R3 EC3 series 100-240VAC 36DI 24DO relay output in box | Обустройство дома



Electrical Specifications
| Model Item | 10EC 00_3 | 14EC 00_3 | 16EC 00_3 | 20EC 00_3 | 24EC 00_3 | 30EC 00_3 | 32EC 00_3 | 40EC 00_3 | 48EC 00_3 | 60EC 00_3 | ||
| Power supply voltage | 100 ~ 240VAC (-15% ~ 10%), 50/60Hz + - 5% | |||||||||||
| Operation | DVP-EC3 starts to run when the power supply rises to 95 ~ 100V AC and stops when the power supply drops to 70V AC. It continues to run for 10ms after the power supply is cut off. | |||||||||||
| Power supply fuse | 2A/250VAC | |||||||||||
| Power consumption | 12VA | 15.6VA | 22.5VA | |||||||||
| DC24V current output | 200mA | 300mA | 400mA | |||||||||
| Power supply | DC24V output short circuit | |||||||||||
| Voltage withstand | 1,500VAC (Primary-secondary), 1,500VAC (Primary-PE), 500VAC (Secondary-PE) | |||||||||||
| Insulation resistance | > 5MΩ at 500VDC (between all I/O points and earth) | |||||||||||
| Noise immunity | ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV, Analog & Communication I/O: 1kV RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m | |||||||||||
| Grounding | The diameter of grounding wire shall not be less than that of L, N terminal of the power supply. (When many PLCs are in use at the same time, please make sure every PLC is properly grounded.) | |||||||||||
| Operation/storage | Operation: 0 °C ~55 °C (temperature), 50~95% (humidity), pollution degree 2 Storage: -25 °C ~70 °C (temperature), 5~95% (humidity) | |||||||||||
| Agency approvals | UL508 European community EMC Directive 89/336/EEC and Low Voltage Directive 73/23/EEC | |||||||||||
| Vibration/shock immunity | International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea) | |||||||||||
| RS-485 Port | No | Yes | ||||||||||
| Weight (g) | R | 205 | 210 | 220 | 310 | 322 | 325 | 340 | 380 | 540 | 560 | |
| T | 192 | 195 | 198 | 285 | 288 | 290 | 295 | 340 | 505 | 510 | ||
Отзывы о Original Delta PLC controller DVP60EC00R3 EC3 series 100-240VAC 36DI 24DO relay output in box Обустройство дома